Amp-hours to watt-hours in one minute
- Wh = Ah × V (use the battery’s nominal voltage)
- Ah = Wh ÷ V
- kWh = Wh ÷ 1,000
- Ah = mAh ÷ 1,000
Example using our R-LFP12.8V100Ah battery: 100 Ah × 12.8 V = 1,280 Wh = 1.28 kWh.
If you are comparing batteries for a caravan, an off-grid cabin or a home storage system in Australia, amp-hours alone will not tell you which one stores more energy. Watt-hours will. This guide shows the formula, which voltage to plug in, and a quick table for common 12, 24 and 48 V platforms.
The formula, and the units behind it
The SI definitions make the maths simple. NIST defines the watt as a joule per second, the volt as a watt per ampere and the coulomb as an ampere-second. This gives watts = volts × amps. Source: NIST Guide to the SI, Chapter 4, Table 3. NIST unit definitions.
That gives three different things:
- A (amps) is current: how fast charge is flowing.
- Ah (amp-hours) is charge: 1 Ah = 3,600 coulombs.
- Wh (watt-hours) is energy: charge multiplied by voltage.

Multiply amp-hours by volts and you get watt-hours. Divide watt-hours by volts and you get amp-hours back. Two quick examples:
- 5,120 Wh ÷ 51.2 V nominal = 100 Ah (hypothetical arithmetic · LiFePO4 · pack-level)
- 6,000 mAh ÷ 1,000 × 3.2 V nominal = 19.2 Wh (hypothetical arithmetic · LiFePO4 · cell-level)
For a 100 Ah battery, 0.5C corresponds to 50 A. This relates current to capacity; it does not change the Ah-to-Wh formula.
Which voltage to use: nominal, not what your meter shows
The V in the formula is where most conversions go wrong. A battery’s terminal voltage moves with state of charge, load and temperature, so a multimeter reading, a full-charge voltage or a charging voltage will all give a different answer. Use the nominal voltage the maker prints on the datasheet. It is the stable reference the rated energy is calculated from.
For our lithium iron phosphate (LiFePO4, LFP) packs, use the voltage listed for the exact model. Our standard and RESU R1 product tables include 12.8 V, 25.6 V and 51.2 V models. The table below illustrates series arithmetic using 3.2 V per cell; always use the finished pack specification for conversion.
T2 — Nominal voltage by chemistry and platform
| Chemistry | Per cell (nominal) | “12 V” class | “24 V” class | “48 V” class | Source |
|---|---|---|---|---|---|
| LiFePO4 | 3.2 V | 4S = 12.8 V | 8S = 25.6 V | 16S = 51.2 V | Our standard / RESU R1 product parameters; 3.2 V series arithmetic is illustrative |
| Lead-acid | about 2 V | 6 cells = 12 V | 12 cells = 24 V | 24 cells = 48 V | DOE-HDBK-1084-95, pp. 7–9 |
For lead-acid batteries, the U.S. Department of Energy describes a 12 V battery as six cells of about 2 V in series. Its primer also explains that terminal voltage changes during discharge. Use the rated nominal voltage rather than a live meter reading.
For our R-LFP12.8V100Ah model, use 12.8 V for conversion. For a lead-acid battery rated at 12 V, use 12 V. Check the exact model specification rather than relying on the system class in its name. A voltage reading alone does not establish how much usable energy remains.
Worked examples from our product parameters — Ah × rated voltage
- Our R-LFP12.8V100Ah: 100 Ah × 12.8 V = 1,280 Wh = 1.28 kWh. Voltage and capacity come from the Parameters table; Wh and kWh are calculated here.
- Our RESU R1 R-LFP51.2V100Ah: 100 Ah × 51.2 V = 5,120 Wh = 5.12 kWh. Voltage and capacity come from the product parameter table; Wh and kWh are calculated here.
These are pack-level calculations using our published rated voltage and capacity. They are not capacity-test results or guarantees of usable energy. Confirm the exact model and its test conditions before sizing a system.
Quick conversion table
T1 — Amp-hours to watt-hours (illustrative arithmetic · nominal voltage · pack-level; not our product range)
| Ah | 12 V lead-acid | 12.8 V LFP | 24 V lead-acid | 25.6 V LFP | 48 V lead-acid | 51.2 V LFP |
|---|---|---|---|---|---|---|
| 50 Ah | 600 Wh | 640 Wh | 1,200 Wh | 1,280 Wh | 2,400 Wh | 2,560 Wh |
| 100 Ah | 1,200 Wh | 1,280 Wh | 2,400 Wh | 2,560 Wh | 4,800 Wh | 5,120 Wh |
| 200 Ah | 2,400 Wh | 2,560 Wh | 4,800 Wh | 5,120 Wh | 9,600 Wh | 10,240 Wh |
| 300 Ah | 3,600 Wh | 3,840 Wh | 7,200 Wh | 7,680 Wh | 14,400 Wh | 15,360 Wh |
To get kWh, divide by 1,000 (for example, 10,240 Wh = 10.24 kWh). Going the other way for a home storage target: 5 kWh ÷ 51.2 V ≈ 97.7 Ah and 10 kWh ÷ 51.2 V ≈ 195.3 Ah (hypothetical arithmetic · nominal · pack-level). All values are nameplate energy, rounded where needed.
Cells, packs, series and parallel
For matched batteries, series connection adds voltage while Ah stays the same; parallel connection adds Ah while voltage stays the same. Total nominal Wh is the sum of the individual batteries’ nominal Wh in the ideal calculation.
T3 — Series vs parallel(hypothetical arithmetic · nominal · pack-level · matched batteries)
| Configuration | Nominal V | Ah | Wh |
|---|---|---|---|
| 1 × 12.8 V 100 Ah | 12.8 V | 100 Ah | 1,280 Wh |
| 2 in series | 25.6 V | 100 Ah | 2,560 Wh |
| 2 in parallel | 12.8 V | 200 Ah | 2,560 Wh |
| 4 in series | 51.2 V | 100 Ah | 5,120 Wh |
The same logic links cells to packs. Sixteen 3.2 V cells of 100 Ah in series give 51.2 V and 16 × 320 Wh = 5,120 Wh (hypothetical arithmetic · cell → pack, ideal). Real packs carry a BMS and interconnects, so always read the pack datasheet rather than multiplying a cell datasheet yourself. Only combine matched batteries, within the maker’s stated series and parallel limits.
Box B1 — How to label an Ah↔Wh example
[Ah] × [nominal V] = [Wh] · cell or pack · source, or “hypothetical arithmetic”
e.g. 200 Ah × 25.6 V = 5,120 Wh · pack · hypothetical arithmetic
Same amp-hours, different energy
Is a 100 Ah lithium battery the same as a 100 Ah lead-acid battery? On energy, no:
- 100 Ah × 12.8 V nominal (LiFePO4) = 1,280 Wh
- 100 Ah × 12 V nominal (lead-acid) = 1,200 Wh

That is 80 Wh more nameplate energy from the same Ah rating (hypothetical arithmetic · nominal · pack-level). Across platforms the gap is bigger: 100 Ah at 51.2 V is 5,120 Wh, four times 100 Ah at 12.8 V.
This matters when you compare quotes for an RV build or an off-grid shed. If one supplier quotes Ah at 12.8 V and another quotes Ah at 48 V, the Ah numbers are not comparable. Convert both to kWh at their nominal voltage first. How much of that nameplate energy you can actually draw differs by chemistry, which is a separate question.
Nameplate Wh is not usable Wh
The conversion gives nominal energy. As a planning estimate, usable Wh ≈ nominal Wh × allowed depth of discharge × system efficiency. Use the discharge limit and efficiency that apply to your system. Runtime then depends on the load: hours ≈ usable Wh ÷ average load in watts. The table above compares nominal energy; it does not predict runtime.
Reading Ah, V and Wh on a datasheet
Use this checklist when you check any battery’s numbers:
- Is the nominal voltage stated? If not, ask for it before converting.
- Does Ah × rated voltage match the stated energy? Our R-LFP12.8V100Ah gives 1,280 Wh and our RESU R1 R-LFP51.2V100Ah gives 5,120 Wh by calculation. If a specification lists a different Wh value, check rounding, rating conditions and the exact model before comparing.
- What discharge rate, temperature and cut-off voltage apply to the capacity rating? Our public parameter tables list rated voltage and Ah but do not establish a capacity-test method. Ask us for the model-specific datasheet and test conditions before treating a calculation as measured energy.
- Is it a cell or a pack figure? A cell datasheet is not a pack spec.
- For lead-acid, which hour rate? The DOE primer notes common 8-, 10- and 20-hour ratings and explains that capacity falls at higher discharge rates. A C/20 rating and a C/10 rating use different test currents, so compare capacities at the same rate.
FAQ
How many watt-hours is a 12 V 100 Ah battery?
It depends on chemistry. A 12 V lead-acid battery: 100 Ah × 12 V = 1,200 Wh. A LiFePO4 battery sold as “12 V” is 12.8 V nominal: 100 Ah × 12.8 V = 1,280 Wh.
How do I convert watt-hours to amp-hours?
Divide by nominal voltage: Ah = Wh ÷ V. For example, 2,560 Wh ÷ 25.6 V = 100 Ah.
How do I convert mAh to Wh?
Divide mAh by 1,000 to get Ah, then multiply by nominal voltage. A 3,000 mAh LiFePO4 cell at 3.2 V = 3 Ah × 3.2 V = 9.6 Wh.
Why is a LiFePO4 “12 V” battery 12.8 V?
Four cells rated at 3.2 V in series give 12.8 V. Our R-LFP12.8V100Ah product table lists 12.8 V, so use that value to convert its Ah to Wh.
Does wiring in series or parallel change total Wh?
For matched batteries in the ideal calculation, total Wh is the sum of their individual Wh. Series adds voltage; parallel adds Ah. Follow the exact model’s connection limits. See DOE-HDBK-1084-95, pp. 8–9, for these principles.
Is Wh the same as usable energy or runtime?
The Ah × nominal V calculation estimates nominal energy. Usable energy also depends on the allowed discharge window and losses. Divide usable Wh by average load in watts to estimate runtime in hours.

Need real Ah, V and Wh for a LiFePO4 pack?
Browse our LiFePO4 batteries. Tell us your system voltage and target kWh, and we’ll send datasheets showing nominal voltage, Ah and the test conditions behind them.